Mixing Mismatched Solar Panels? Why Voltage and Current Matching Matters in Series and Parallel

by chenli fang 26 Aug 2026 0 comments

Solar arrays are rarely built from a single box of perfectly identical panels, and that is exactly where voltage and current matching becomes the difference between a system that performs exactly as designed and one that quietly underperforms every single day. Whether you are expanding an existing array, mixing old and new panels, or combining panels from two different manufacturers, the electrical compatibility of those panels determines how much of the energy they are capable of producing actually reaches your batteries. In this guide, we will break down the rules of matching panels in series and parallel, show you exactly how the "weakest link" principle works with real numbers, and give you a practical method for testing and combining mismatched panels so your array stays safe, efficient, and long-lasting.

DIY BATTERY KITS

Why Voltage and Current Matching Matters When Mixing Solar Panels

Every solar panel has two electrical identities that govern how it behaves in a circuit: its operating voltage and its operating current. The voltage is the electrical "pressure" the panel pushes with, while the current is the rate at which charge flows through the wire. A panel produces maximum power only when it operates at its maximum power point, which is the product of the maximum power voltage (Vmp) and the maximum power current (Imp). When you connect several panels together, the way they share voltage and current changes fundamentally, and a mismatch between them forces one or more panels away from that maximum power point. That is the entire reason voltage and current matching matters so much in a mixed array.

In a series connection, all panels are wired end to end like links in a chain, and the same electrical current must flow through every single panel. In a parallel connection, panels are wired side by side and must all operate at the same voltage. These two facts sound simple, but they have profound consequences. If one panel in a series string can only deliver 5 amps, the entire string is dragged down to 5 amps, no matter how powerful the other panels are. If one panel in a parallel bank can only reach 18 volts, the whole bank is clamped at 18 volts, even if its neighbors are capable of 36 volts. In both cases, the weakest panel silently robs the stronger panels of their capacity.

This matters more than most people expect because even panels with the same wattage rating can have very different voltage and current characteristics. A "100 watt" panel is not a universal standard. Depending on whether it is a 12-volt nominal, 18-volt nominal, or 24-volt nominal design, and depending on the number and type of its internal cells, its Vmp could be 17 volts, 18 volts, 20 volts, 34 volts, or 36 volts, and its Imp could range from under 3 amps to over 10 amps. Mixing two panels that both say "100W" on the label can still produce a significant mismatch, which is why proper voltage and current matching must be verified on the actual specs, not assumed from the wattage.

The Two Numbers That Define a Panel

To understand voltage and current matching, you need to know the four key ratings printed on the back of every panel's specification sticker. The first two are the open-circuit voltage (Voc) and the short-circuit current (Isc), which are the maximum voltage and current the panel can produce when disconnected and shorted respectively. These are the safety-critical numbers used to size charge controllers and wiring. The second two are the maximum power voltage (Vmp) and maximum power current (Imp), which are the voltage and current the panel produces at its best operating point, the point where it actually delivers its rated wattage. When we talk about matching panels, Vmp and Imp are the numbers that determine real-world performance.

How Mismatch Turns Power Into Heat

When panels are mismatched, the lost potential is not simply vaporized; much of it is converted into heat inside the cells and can even damage them over time. A strong panel forced to run below its natural current will still capture the same amount of sunlight, but because it cannot deliver the excess as current, the energy dissipates internally. In extreme cases, especially in parallel configurations without blocking diodes, a higher-voltage panel can push reverse current back through a lower-voltage panel at night or in shade, overheating it and shortening its life. This is why voltage and current matching is as much a reliability issue as it is an efficiency issue.

Why This Matters When Expanding an Array

The most common real-world scenario for mismatched panels is expansion. Someone starts with two 200-watt panels, and a year later buys two more, only to discover the new panels are a different brand, a different model, or a different cell technology with slightly different Vmp and Imp values. The temptation is to bolt them on and hope for the best, but the result is almost always a system that produces less than the sum of its parts. Understanding the rules of voltage and current matching lets you decide whether those new panels belong in series, in parallel, on a separate charge controller, or not in the same circuit at all.

The Rules of Voltage and Current Matching in Series Connections

When panels are wired in series, the positive terminal of one panel connects to the negative terminal of the next, and the voltages add together while the current stays the same through the entire string. A string of four panels, each with a Vmp of 36 volts and an Imp of 6.1 amps, produces a combined Vmp of 144 volts at a current of 6.1 amps, for a total of roughly 880 watts. This is the classic 4×220W example: four 220-watt panels that are truly identical will deliver nearly 880 watts of clean power. But the moment a different panel joins the string, the current rule becomes the dominant constraint, and that is where the rules of voltage and current matching in series come into play.

The first and most important rule of series connections is that the current is limited to the lowest-current panel in the string. Every panel in a series circuit must pass the exact same amount of current, because there is only one path for electricity to flow. If one panel can only deliver 5.5 amps while the others can deliver 6.1 amps, the entire string drops to 5.5 amps. The stronger panels do not get to "make up" the difference; they are simply throttled down to match the weakest panel, and their extra capacity is lost. This is the purest example of the weakest-link principle in solar system design.

The second rule is that voltages should be closely similar, even though they are technically additive. The voltage of the string is simply the sum of all panel voltages, so a 36-volt panel and an 18-volt panel in series would produce 54 volts with no mathematical penalty at the voltage level. However, because the current must match, the panel with the lower current drags the whole string down, and the panel with the lower voltage often also carries the lower current, compounding the loss. The takeaway is that in series, you want panels whose Imp values match as closely as possible, and similar Vmp values help keep everything behaving predictably.

Calculating a Series String With a Mismatched Panel

Let us run the numbers on the 4×220W example with one mismatched panel added. Imagine you have four 220-watt panels, each with a Vmp of 36 volts and an Imp of 6.1 amps. Wired in series, they produce 144 volts at 6.1 amps, or about 878 watts. Now suppose you add a fifth panel that is rated at 100 watts with a Vmp of 18 volts and an Imp of 5.5 amps. The string's voltage becomes 36 + 36 + 36 + 36 + 18, or 162 volts, but the current collapses to the weakest panel's 5.5 amps. The total power is now 162 volts times 5.5 amps, or about 891 watts. The four big panels, previously delivering 220 watts each, now deliver only about 198 watts each, and your new 100-watt panel contributes only 99 watts. You added a panel and gained almost nothing because the mismatch throttled the entire string.

An Even More Dramatic Mismatch

The loss becomes far more painful when the mismatch is between a low-voltage, high-current panel and a high-voltage, low-current panel. Consider a 200-watt 12-volt panel with a Vmp of 17 volts and an Imp of 11.8 amps, wired in series with a 200-watt 24-volt panel with a Vmp of 36 volts and an Imp of 5.5 amps. The voltages add to 53 volts, but the current is forced down to 5.5 amps by the second panel. The 12-volt panel, which is capable of 200 watts, now contributes only 17 volts times 5.5 amps, or about 93 watts. The two panels together produce about 291 watts instead of 400 watts, a loss of more than 27 percent. This is why the rules of voltage and current matching in series are non-negotiable: a single mismatched panel can waste more energy than it adds.

Using a Higher Voltage Is Often Fine, Higher Current Is Not

There is an important nuance in series matching that confuses many beginners. Adding a panel with a higher voltage rating than the others is generally acceptable as long as its current is equal to or greater than the rest of the string, because the voltage will simply add on top and the current will stay at the shared level. The danger in series is almost always a panel with lower current, because that lower current becomes the ceiling for every panel in the string. When you select panels for a series string, therefore, the single most important number to match is the Imp, the maximum power current. Vmp matters too, but it is the current matching that protects you from the worst losses.

The Rules of Voltage and Current Matching in Parallel Connections

Parallel connections are the mirror image of series connections. When panels are wired in parallel, all positive terminals are joined together and all negative terminals are joined together, so every panel operates at the same voltage while the currents add together. Four identical 220-watt panels with a Vmp of 36 volts and an Imp of 6.1 amps, wired in parallel, produce 36 volts at a combined current of 24.4 amps, for the same roughly 878 watts as the series arrangement. The difference is that in parallel, the voltage is the shared quantity and the current is the additive one, which flips the matching priorities entirely.

The first rule of parallel connections is that the voltage is clamped to the lowest-voltage panel in the bank. Because all panels are connected to the same two bus bars, they physically cannot operate at different voltages; they must all sit at the same potential. If one panel wants to run at 18 volts and the others want to run at 36 volts, the entire bank is pulled down toward the lower voltage, because that is the point where the combined current actually flows. The higher-voltage panels are forced to operate far below their maximum power point, and their output collapses. In parallel, the weakest link is defined by voltage rather than current.

The second rule is that currents should be similar, even though they are technically additive. The current of a parallel bank is simply the sum of all panel currents, so a 5-amp panel and a 10-amp panel in parallel would produce 15 amps with no penalty at the current level. However, panels with very different current ratings often also have very different voltage ratings, and it is that voltage difference that creates the problem. The key insight is that in parallel, you want Vmp values to match closely, and similar Imp values are a bonus that keeps the bank balanced and easier to protect with fuses and breakers.

Calculating a Parallel Bank With a Mismatched Panel

Return to the 200-watt example, but this time wire the panels in parallel. You have one 200-watt 12-volt panel with a Vmp of 17 volts and an Imp of 11.8 amps, and one 200-watt 24-volt panel with a Vmp of 36 volts and an Imp of 5.5 amps. Connected in parallel, both panels are forced to the lower voltage of about 17 volts. The 24-volt panel, which wants to run at 36 volts, is dragged down to 17 volts and can only deliver its 5.5 amps, producing about 93 watts instead of 200. The combined output is 17 volts times 16.3 amps, or about 277 watts, versus the 400 watts you should have. The higher-voltage panel has lost more than half its capacity simply because the bank was clamped to the lower panel's voltage.

Reverse Current and the Danger of Unequal Voltages

Parallel mismatching carries a hidden danger that series mismatching does not: reverse current flow. In a series string, the current is the same everywhere and there is no path for one panel to drive current backward through another. In a parallel bank, if one panel's voltage is higher than another's, the higher-voltage panel can push current into the lower-voltage panel, especially when that lower panel is shaded, dirty, or simply lower voltage by design. This reverse current can heat the weaker panel and, over time, permanently damage its cells. That is why parallel banks of mismatched panels should always include blocking diodes, which act like one-way valves that prevent current from flowing backward into a panel.

Lower Current Is Usually Fine in Parallel, Lower Voltage Is Not

Just as series connections tolerate higher voltage but not lower current, parallel connections tolerate lower current but not lower voltage. Adding a panel with a lower current rating to a parallel bank is harmless as long as its voltage matches the rest of the bank, because it will simply contribute its smaller share of the total current. The danger in parallel is almost always a panel with lower voltage, because that lower voltage drags every other panel down to its level. When you select panels for a parallel bank, the single most important number to match is the Vmp, the maximum power voltage, while the Imp should ideally be in the same ballpark to keep the wiring and protection simple.

View more>>Solar Panel Combiner Boxes, Fuses, and Breakers: Protecting Your Series-Parallel Array

What Happens When You Ignore Voltage and Current Matching

The consequences of ignoring voltage and current matching range from mildly disappointing to genuinely dangerous, and most installers who skip this step discover the problem slowly, in the form of a system that just never seems to produce what it should. The most common outcome is silent underperformance, where the array produces less power than the rated total of its panels but nothing obviously appears broken. The panels are all in the sun, the charge controller reports current, and yet the battery bank fills more slowly than expected. The cause is almost always a mismatch that is throttling the strong panels down to the level of the weakest one.

A more serious consequence is localized overheating and permanent damage. When a strong panel is forced to operate far from its maximum power point, or when reverse current flows backward through a weaker panel, the excess energy becomes heat concentrated in the cells. This heat accelerates cell degradation, can burn through solder joints, and in severe cases can cause the encapsulant to yellow and the panel to fail prematurely. In parallel banks without blocking diodes, reverse current can literally cook a shaded or lower-voltage panel over the course of a few seasons, turning a modest wiring shortcut into an expensive replacement.

There are also safety implications that go beyond performance and panel life. A mismatched array can exceed the voltage or current limits of its charge controller, wiring, and fuses in unexpected ways, because the installer may have sized those components for the matched array and not accounted for the mismatch. An undersized wire carrying a higher current than expected can overheat, and an undersized charge controller can be pushed past its maximum input voltage. Ignoring voltage and current matching, in other words, does not just waste watts; it can create conditions that stress every component downstream of the panels.

How Much Power You Actually Lose

The numbers make the cost of ignoring matching painfully clear. In the series example with a 200-watt 12-volt panel and a 200-watt 24-volt panel, the mismatch reduced output from 400 watts to about 291 watts, a loss of more than a quarter of the array's capacity. In the parallel version of the same pair, the loss was even worse, dropping to about 277 watts. Across a full year of sunlight, a 100-watt loss represents a large fraction of the array's total production, and the gap only widens as the array grows. Every mismatched panel you add to the wrong circuit is a panel whose purchase price you are not recovering in energy.

The Cost of Repairing the Damage

The financial hit does not stop at the lost wattage. Panels damaged by reverse current or long-term overheating have to be replaced, and that replacement panel will cost far more than the time it would have taken to test and match the array properly in the first place. There is also the labor cost of climbing back onto the roof or dismantling a ground mount to swap a burned panel, and the downtime of a system that is not producing while the repair is scheduled. Ignoring voltage and current matching is a false economy that turns a free twenty-minute testing session into a multi-hundred-dollar repair.

The "It Works Anyway" Trap

The reason so many mismatched arrays stay in service is that they do produce some power, and the installer never sees a fault code or an error message. A mismatched array rarely fails all at once; it just underperforms quietly, and the owner has no baseline to compare against. This is the "it works anyway" trap, and it is exactly why understanding voltage and current matching from the start matters. Once you know what a properly matched array should produce, you can spot the shortfall, diagnose the mismatch, and fix it before it silently drains your system's potential for years.

How to Test Panels for Voltage and Current Matching

Before you connect any panels together, you should verify their actual electrical characteristics with your own eyes and your own meter, because the printed label does not always tell the whole story. Panels degrade over time, accumulate dust and micro-cracks, and sometimes ship with a slightly different configuration than the datasheet implies. Testing each panel allows you to perform voltage and current matching on real, measured values rather than optimistic specifications, which is the only way to guarantee that your series string or parallel bank will behave the way your calculations predict. The good news is that the testing procedure is simple and requires nothing more than a digital multimeter and a sunny day.

The two measurements that matter most for matching are the open-circuit voltage (Voc) and the short-circuit current (Isc), which are safe, easily measured values that give you a reliable snapshot of a panel's health and its compatibility with other panels. Voc tells you roughly where the panel's voltage will sit, and Isc tells you roughly where its current will sit. The maximum power values, Vmp and Imp, are harder to measure directly without specialized equipment, but Voc and Isc correlate closely enough with them that panels with similar Voc and Isc are almost always well matched. A multimeter that can read DC voltage and DC current up to at least 10 amps is all you need for the task.

There is one crucial safety rule for this testing: never measure current while the panel is connected to a load, and never measure voltage while the meter is set to the current mode. You should also perform all current measurements with the meter in series with the panel's own shorted leads, and only for panels whose short-circuit current is within your meter's rating, which is usually 10 amps for a standard multimeter. Larger panels can exceed that, so for high-current panels you will need a clamp meter or a meter with a higher current range. Testing should also be done in full, direct sunlight at the same time of day for every panel, so that all panels are measured under identical conditions.

Step-by-Step Multimeter Test

To measure open-circuit voltage, set your multimeter to DC volts, disconnect the panel from any circuit, and place the probes on the panel's positive and negative leads while it faces the sun. The reading is the Voc. Write it down for each panel. To measure short-circuit current, set the meter to the DC amp range, connect the meter in series with the panel by clipping one probe to the positive lead and the other to the negative lead, and read the current that flows through the short. This is the Isc. Record it for every panel. Panels that are healthy and compatible will show Voc and Isc values within about 5 percent of one another.

Interpreting the Numbers

Once you have a list of Voc and Isc values for all your panels, the matching decision becomes straightforward. For a series string, group panels whose Isc values are within about 5 percent of each other, because the current will be limited to the lowest Isc in the group and you want that number to be as high and as uniform as possible. For a parallel bank, group panels whose Voc values are within about 5 percent of each other, because the voltage will be clamped to the lowest Voc in the group. Panels that fail to fit into either group with reasonable closeness are strong candidates for a separate charge controller or a separate array rather than being forced into the same circuit.

Checking Panel Health at the Same Time

This same test doubles as a health check that can reveal hidden problems before they affect the rest of your system. A panel whose Voc is dramatically lower than its label, or lower than its siblings, may have damaged cells, moisture intrusion, or a failed bypass diode. A panel whose Isc is far below expectations may be suffering from delamination, hot spots, or heavy shading from a nearby tree or vent. By testing every panel individually before wiring them together, you catch these problems early, and you make better voltage and current matching decisions based on what the panels actually do in the real world rather than what their stickers promise.

Strategies for Voltage and Current Matching with Mismatched Panels

Sometimes you do not have the luxury of buying identical panels, and you must work with the mismatched panels you already own. The good news is that there are several proven strategies for voltage and current matching that let you squeeze maximum value out of a mixed collection of panels without sacrificing safety. The right strategy depends on how badly the panels are mismatched, how many you have, and whether your charge controller supports multiple inputs. In every case, the goal is the same: keep strong panels from being throttled by weak ones, and keep reverse current from flowing where it should not.

The first and most powerful strategy is to use separate charge controllers for separate groups of panels. If you have a group of 36-volt panels and a group of 18-volt panels, each group can be wired into its own independent array feeding its own MPPT charge controller, with both controllers charging the same battery bank. This completely eliminates the mismatch because the two groups never share a circuit, and an MPPT controller extracts maximum power from each group independently. Modern MPPT charge controllers are inexpensive enough that this is often cheaper than trying to force incompatible panels into a single string.

Another effective approach is to build a series-parallel hybrid, where you form multiple series strings of well-matched panels and then wire those strings in parallel. This is the most common configuration for larger arrays, because it lets you raise the voltage to a practical level while keeping the current within reasonable limits, and it gives you fine control over matching. Each series string should contain panels with matched current, and each parallel string should have a voltage closely matched to the other strings. A hybrid array of four 220-watt panels, for example, could be two strings of two panels in series, wired in parallel, producing 72 volts at 12.2 amps.

For smaller mismatches, passive components can correct the problem at low cost. Blocking diodes in parallel banks prevent reverse current and protect weaker panels, and they are cheap, simple, and effective insurance. Power optimizers, which are small DC-to-DC converters attached to each panel, take this further by actively adjusting each panel's operating point so that a shaded or mismatched panel does not drag down its neighbors. Optimizers are more expensive but essentially solve the mismatch problem at the source, and they are especially valuable when partial shading is a concern.

Grouping Panels by Measured Values

The cheapest and most reliable strategy is simply to group your panels by their measured Voc and Isc values, using the multimeter test described earlier. Sort all of your panels by Isc for series applications and by Voc for parallel applications, then form groups where the relevant value is within about 5 percent of the group average. A panel that does not fit neatly into any group can be set aside for a dedicated micro-inverter, a dedicated small charge controller, or a future expansion. This method costs nothing but a little organization and yields dramatic improvements in total array output.

Choosing the Right Configuration for Each Panel

Once your panels are grouped, the configuration decision follows directly from their characteristics. High-voltage, low-current panels are happiest in series, where their voltage can stack and their modest current is not a liability. Low-voltage, high-current panels are happiest in parallel, where their current can add and their low voltage is not a penalty. By matching the wiring topology to each panel's nature, you let every panel run near its maximum power point, which is the entire goal of voltage and current matching. A well-planned mixed array can recover nearly all of the performance that a careless series or parallel hookup would throw away.

Using Micro-Inverters and Optimizers to End the Debate

For anyone who wants to stop worrying about matching altogether, module-level power electronics are the definitive answer. Micro-inverters convert each panel's DC output to AC at the panel itself, so every panel operates independently and a weak panel never affects its neighbors. Power optimizers perform a similar role while still feeding a central inverter. Both solutions cost more up front, but they make voltage and current matching a non-issue and often pay for themselves in recovered production, especially on roofs with partial shading or mixed panel types. If your budget allows, this is the most robust long-term strategy for a mismatched array.

View more>>Can You Build a 30kWh Home Battery Yourself?

Voltage and Current Matching: Best Practices for a Reliable Array

Everything in this guide points toward a single conclusion: a little planning at the wiring stage saves years of underperformance and a pile of repair bills down the road. The best practices for voltage and current matching are not complicated, but they require discipline, and they should be applied every single time you add, replace, or rearrange a panel. If you commit to these habits, your array will run at its true potential, your components will stay within their safe limits, and your panels will last as long as their manufacturers intend them to last.

The first best practice is to buy panels in matched batches whenever you can. Identical panels from the same manufacturer and the same production run will have nearly identical Vmp and Imp values, which makes matching trivial and eliminates most of the risk discussed here. If you know you will expand later, buy a spare panel or two now, while the same model is still available, rather than gambling that a compatible panel will be on the shelf next year. A spare panel on a shelf is the cheapest insurance a solar system can have.

The second best practice is to test every panel before it goes into the array, every time, without exception. Even panels from the same batch can differ slightly, and a quick multimeter check of Voc and Isc will confirm that each panel is healthy and compatible before you commit it to a series string or a parallel bank. Record your measurements in a notebook or a spreadsheet so that you always know the real electrical identity of every panel in your system, and so that future expansions can be matched against actual data rather than memory.

The third best practice is to respect the limits of your downstream equipment. When you calculate the total Voc and Isc of your final array, you must size your charge controller, fuses, breakers, and wire to handle those values with margin, including the temperature-corrected maximum voltage on cold mornings when panels produce their highest output. A mismatched array can push these limits in surprising directions, so build in headroom and recheck the math every time the array changes. Safety always comes before efficiency.

Buy Matched, Test Everything, Document Everything

If you remember only three habits from this article, make them these: buy matched panels, test every panel before installation, and document every measurement and connection. These three habits cover the vast majority of voltage and current matching failures in the real world. Buying matched panels removes the root cause, testing catches the problems that shipping and aging introduce, and documentation gives you a reliable map of your system that pays off the moment you decide to expand, troubleshoot, or sell the property.

Plan Your Topology Before You Cut a Single Wire

Before you connect anything, draw out your array on paper and run the voltage and current numbers for the chosen topology. For a series string, add up the Voc of every panel and confirm the total stays below your charge controller's maximum input voltage, and confirm that every panel's Isc is close to the string's shared current. For a parallel bank, confirm that every panel's Voc is close to the shared voltage and that the combined Isc stays within your wiring and fuse ratings. Five minutes of arithmetic at the kitchen table prevents hours of troubleshooting on the roof.

Recheck Your Array Whenever It Changes

The final best practice is to treat your array as a living system that changes over time, and to reapply the principles of voltage and current matching whenever it grows, shrinks, or ages. Panels degrade, trees grow, components get replaced, and every one of those changes can shift the balance of your array. A configuration that was perfectly matched five years ago may be mismatched today after a panel replacement or a new addition. By re-testing and re-evaluating periodically, you keep your array performing at its best for its entire working life, which is exactly what good voltage and current matching is designed to achieve.

EVE MB31 AND MB56 Cells

Prev post
Next post

Leave a comment

All blog comments are checked prior to publishing

Thanks for subscribing!

This email has been registered!

Shop the look

Choose options

Edit option
Back In Stock Notification
Compare
Product SKU Description Collection Availability Product type Other details
Terms & conditions

This website is operated by Wistek. Throughout the site, the terms “we”, “us” and “our” refer to Wistek. Wistek offers this website, including all information, tools and Services available from this site to you, the user, conditioned upon your acceptance of all terms, conditions, policies and notices stated here

By visiting our site and/ or purchasing something from us, you engage in our “Service” and agree to be bound by the following terms and conditions (“Terms of Service”, “Terms”), including those additional terms and conditions and policies referenced herein and/or available by hyperlink. These Terms of Service apply to all users of the site, including without limitation users who are browsers, vendors, customers, merchants, and/ or contributors of content.

Please read these Terms of Service carefully before accessing or using our website. By accessing or using any part of the site, you agree to be bound by these Terms of Service. If you do not agree to all the terms and conditions of this agreement, then you may not access the website or use any Services. If these Terms of Service are considered an offer, acceptance is expressly limited to these Terms of Service.

Any new features or tools which are added to the current store shall also be subject to the Terms of Service. You can review the most current version of the Terms of Service at any time on this page. We reserve the right to update, change or replace any part of these Terms of Service by posting updates and/or changes to our website. It is your responsibility to check this page periodically for changes. Your continued use of or access to the website following the posting of any changes constitutes acceptance of those changes.

Our store is hosted on Shopify Inc. They provide us with the online e-commerce platform that allows us to sell our products and Services to you.

SECTION 1 - ONLINE STORE TERMS By agreeing to these Terms of Service, you represent that you are at least the age of majority in your state or province of residence, or that you are the age of majority in your state or province of residence and you have given us your consent to allow any of your minor dependents to use this site. You may not use our products for any illegal or unauthorized purpose nor may you, in the use of the Service, violate any laws in your jurisdiction (including but not limited to copyright laws). You must not transmit any worms or viruses or any code of a destructive nature. A breach or violation of any of the Terms will result in an immediate termination of your Services.

SECTION 2 - GENERAL CONDITIONS We reserve the right to refuse Service to anyone for any reason at any time. You understand that your content (not including credit card information), may be transferred unencrypted and involve (a) transmissions over various networks; and (b) changes to conform and adapt to technical requirements of connecting networks or devices. Credit card information is always encrypted during transfer over networks. You agree not to reproduce, duplicate, copy, sell, resell or exploit any portion of the Service, use of the Service, or access to the Service or any contact on the website through which the Service is provided, without express written permission by us. The headings used in this agreement are included for convenience only and will not limit or otherwise affect these Terms.

SECTION 3 - ACCURACY, COMPLETENESS AND TIMELINESS OF INFORMATION We are not responsible if information made available on this site is not accurate, complete or current. The material on this site is provided for general information only and should not be relied upon or used as the sole basis for making decisions without consulting primary, more accurate, more complete or more timely sources of information. Any reliance on the material on this site is at your own risk. This site may contain certain historical information. Historical information, necessarily, is not current and is provided for your reference only. We reserve the right to modify the contents of this site at any time, but we have no obligation to update any information on our site. You agree that it is your responsibility to monitor changes to our site.

SECTION 4 - MODIFICATIONS TO THE SERVICE AND PRICES Prices for our products are subject to change without notice. We reserve the right at any time to modify or discontinue the Service (or any part or content thereof) without notice at any time. We shall not be liable to you or to any third-party for any modification, price change, suspension or discontinuance of the Service.

SECTION 5 - PRODUCTS OR SERVICES (if applicable) Certain products or Services may be available exclusively online through the website. These products or Services may have limited quantities and are subject to return or exchange only according to our Refund Policy: [LINK TO REFUND POLICY] We have made every effort to display as accurately as possible the colors and images of our products that appear at the store. We cannot guarantee that your computer monitor's display of any color will be accurate. We reserve the right, but are not obligated, to limit the sales of our products or Services to any person, geographic region or jurisdiction. We may exercise this right on a case-by-case basis. We reserve the right to limit the quantities of any products or Services that we offer. All descriptions of products or product pricing are subject to change at anytime without notice, at the sole discretion of us. We reserve the right to discontinue any product at any time. Any offer for any product or Service made on this site is void where prohibited. We do not warrant that the quality of any products, Services, information, or other material purchased or obtained by you will meet your expectations, or that any errors in the Service will be corrected.

SECTION 6 - ACCURACY OF BILLING AND ACCOUNT INFORMATION We reserve the right to refuse any order you place with us. We may, in our sole discretion, limit or cancel quantities purchased per person, per household or per order. These restrictions may include orders placed by or under the same customer account, the same credit card, and/or orders that use the same billing and/or shipping address. In the event that we make a change to or cancel an order, we may attempt to notify you by contacting the e‑mail and/or billing address/phone number provided at the time the order was made. We reserve the right to limit or prohibit orders that, in our sole judgment, appear to be placed by dealers, resellers or distributors.

You agree to provide current, complete and accurate purchase and account information for all purchases made at our store. You agree to promptly update your account and other information, including your email address and credit card numbers and expiration dates, so that we can complete your transactions and contact you as needed.

For more details, please review our Refund Policy: [LINK TO REFUND POLICY]

SECTION 7 - OPTIONAL TOOLS We may provide you with access to third-party tools over which we neither monitor nor have any control nor input. You acknowledge and agree that we provide access to such tools ”as is” and “as available” without any warranties, representations or conditions of any kind and without any endorsement. We shall have no liability whatsoever arising from or relating to your use of optional third-party tools. Any use by you of the optional tools offered through the site is entirely at your own risk and discretion and you should ensure that you are familiar with and approve of the terms on which tools are provided by the relevant third-party provider(s). We may also, in the future, offer new Services and/or features through the website (including the release of new tools and resources). Such new features and/or Services shall also be subject to these Terms of Service.

SECTION 8 - THIRD-PARTY LINKS Certain content, products and Services available via our Service may include materials from third-parties. Third-party links on this site may direct you to third-party websites that are not affiliated with us. We are not responsible for examining or evaluating the content or accuracy and we do not warrant and will not have any liability or responsibility for any third-party materials or websites, or for any other materials, products, or Services of third-parties. We are not liable for any harm or damages related to the purchase or use of goods, Services, resources, content, or any other transactions made in connection with any third-party websites. Please review carefully the third-party's policies and practices and make sure you understand them before you engage in any transaction. Complaints, claims, concerns, or questions regarding third-party products should be directed to the third-party.

SECTION 9 - USER COMMENTS, FEEDBACK AND OTHER SUBMISSIONS If, at our request, you send certain specific submissions (for example contest entries) or without a request from us, you send creative ideas, suggestions, proposals, plans, or other materials, whether online, by email, by postal mail, or otherwise (collectively, 'comments'), you agree that we may, at any time, without restriction, edit, copy, publish, distribute, translate and otherwise use in any medium any comments that you forward to us. We are and shall be under no obligation (1) to maintain any comments in confidence; (2) to pay compensation for any comments; or (3) to respond to any comments. We may, but have no obligation to, monitor, edit or remove content that we determine in our sole discretion to be unlawful, offensive, threatening, libelous, defamatory, pornographic, obscene or otherwise objectionable or violates any party’s intellectual property or these Terms of Service. You agree that your comments will not violate any right of any third-party, including copyright, trademark, privacy, personality or other personal or proprietary right. You further agree that your comments will not contain libelous or otherwise unlawful, abusive or obscene material, or contain any computer virus or other malware that could in any way affect the operation of the Service or any related website. You may not use a false e‑mail address, pretend to be someone other than yourself, or otherwise mislead us or third-parties as to the origin of any comments. You are solely responsible for any comments you make and their accuracy. We take no responsibility and assume no liability for any comments posted by you or any third-party.

SECTION 10 - PERSONAL INFORMATION Your submission of personal information through the store is governed by our Privacy Policy, which can be viewed here: [LINK TO PRIVACY POLICY]

SECTION 11 - ERRORS, INACCURACIES AND OMISSIONS Occasionally there may be information on our site or in the Service that contains typographical errors, inaccuracies or omissions that may relate to product descriptions, pricing, promotions, offers, product shipping charges, transit times and availability. We reserve the right to correct any errors, inaccuracies or omissions, and to change or update information or cancel orders if any information in the Service or on any related website is inaccurate at any time without prior notice (including after you have submitted your order). We undertake no obligation to update, amend or clarify information in the Service or on any related website, including without limitation, pricing information, except as required by law. No specified update or refresh date applied in the Service or on any related website, should be taken to indicate that all information in the Service or on any related website has been modified or updated.

SECTION 12 - PROHIBITED USES In addition to other prohibitions as set forth in the Terms of Service, you are prohibited from using the site or its content: (a) for any unlawful purpose; (b) to solicit others to perform or participate in any unlawful acts; (c) to violate any international, federal, provincial or state regulations, rules, laws, or local ordinances; (d) to infringe upon or violate our intellectual property rights or the intellectual property rights of others; (e) to harass, abuse, insult, harm, defame, slander, disparage, intimidate, or discriminate based on gender, sexual orientation, religion, ethnicity, race, age, national origin, or disability; (f) to submit false or misleading information; (g) to upload or transmit viruses or any other type of malicious code that will or may be used in any way that will affect the functionality or operation of the Service or of any related website, other websites, or the Internet; (h) to collect or track the personal information of others; (i) to spam, phish, pharm, pretext, spider, crawl, or scrape; (j) for any obscene or immoral purpose; or (k) to interfere with or circumvent the security features of the Service or any related website, other websites, or the Internet. We reserve the right to terminate your use of the Service or any related website for violating any of the prohibited uses.

SECTION 13 - DISCLAIMER OF WARRANTIES; LIMITATION OF LIABILITY We do not guarantee, represent or warrant that your use of our Service will be uninterrupted, timely, secure or error-free. We do not warrant that the results that may be obtained from the use of the Service will be accurate or reliable. You agree that from time to time we may remove the Service for indefinite periods of time or cancel the Service at any time, without notice to you. You expressly agree that your use of, or inability to use, the Service is at your sole risk. The Service and all products and Services delivered to you through the Service are (except as expressly stated by us) provided 'as is' and 'as available' for your use, without any representation, warranties or conditions of any kind, either express or implied, including all implied warranties or conditions of merchantability, merchantable quality, fitness for a particular purpose, durability, title, and non-infringement.

In no case shall Wistek, our directors, officers, employees, affiliates, agents, contractors, interns, suppliers, Service providers or licensors be liable for any injury, loss, claim, or any direct, indirect, incidental, punitive, special, or consequential damages of any kind, including, without limitation lost profits, lost revenue, lost savings, loss of data, replacement costs, or any similar damages, whether based in contract, tort (including negligence), strict liability or otherwise, arising from your use of any of the Service or any products procured using the Service, or for any other claim related in any way to your use of the Service or any product, including, but not limited to, any errors or omissions in any content, or any loss or damage of any kind incurred as a result of the use of the Service or any content (or product) posted, transmitted, or otherwise made available via the Service, even if advised of their possibility. Because some states or jurisdictions do not allow the exclusion or the limitation of liability for consequential or incidental damages, in such states or jurisdictions, our liability shall be limited to the maximum extent permitted by law.

SECTION 14 - INDEMNIFICATION You agree to indemnify, defend and hold harmless Wistek and our parent, subsidiaries, affiliates, partners, officers, directors, agents, contractors, licensors, Service providers, subcontractors, suppliers, interns and employees, harmless from any claim or demand, including reasonable attorneys’ fees, made by any third-party due to or arising out of your breach of these Terms of Service or the documents they incorporate by reference, or your violation of any law or the rights of a third-party.

SECTION 15 - SEVERABILITY In the event that any provision of these Terms of Service is determined to be unlawful, void or unenforceable, such provision shall nonetheless be enforceable to the fullest extent permitted by applicable law, and the unenforceable portion shall be deemed to be severed from these Terms of Service, such determination shall not affect the validity and enforceability of any other remaining provisions.

SECTION 16 - TERMINATION The obligations and liabilities of the parties incurred prior to the termination date shall survive the termination of this agreement for all purposes. These Terms of Service are effective unless and until terminated by either you or us. You may terminate these Terms of Service at any time by notifying us that you no longer wish to use our Services, or when you cease using our site. If in our sole judgment you fail, or we suspect that you have failed, to comply with any term or provision of these Terms of Service, we also may terminate this agreement at any time without notice and you will remain liable for all amounts due up to and including the date of termination; and/or accordingly may deny you access to our Services (or any part thereof).

SECTION 17 - ENTIRE AGREEMENT The failure of us to exercise or enforce any right or provision of these Terms of Service shall not constitute a waiver of such right or provision. These Terms of Service and any policies or operating rules posted by us on this site or in respect to the Service constitutes the entire agreement and understanding between you and us and governs your use of the Service, superseding any prior or contemporaneous agreements, communications and proposals, whether oral or written, between you and us (including, but not limited to, any prior versions of the Terms of Service). Any ambiguities in the interpretation of these Terms of Service shall not be construed against the drafting party.

SECTION 18 - GOVERNING LAW These Terms of Service and any separate agreements whereby we provide you Services shall be governed by and construed in accordance with the laws of Hong Kong.

SECTION 19 - CHANGES TO TERMS OF SERVICE You can review the most current version of the Terms of Service at any time at this page. We reserve the right, at our sole discretion, to update, change or replace any part of these Terms of Service by posting updates and changes to our website. It is your responsibility to check our website periodically for changes. Your continued use of or access to our website or the Service following the posting of any changes to these Terms of Service constitutes acceptance of those changes.

SECTION 20 - CONTACT INFORMATION Questions about the Terms of Service should be sent to us at wistekxr@gmail.com. Our contact information is posted below: wistekxr@gmail.com.

Choose options

this is just a warning
Login
Shopping cart
0 items